Controlled fluid delivery for veterinary clinics and animal hospitals, with a 0.1–1500 ml/h flow range, multiple infusion modes, ultrasonic air-in-line detection and rechargeable battery operation.
Fluid administration is part of many veterinary workflows, from routine treatment and fluid therapy to surgery and post-operative care.
This veterinary infusion pump provides a 0.1–1500 ml/h flow rate, multiple infusion modes and integrated alarm functions in a compact unit. It uses a curvilinear peristaltic pumping mechanism and is compatible with standard IV sets.
The pump also supports bolus and KVO functions, infused volume tracking and rechargeable battery operation, giving veterinary teams several ways to configure and manage an infusion.
Fluid therapy in veterinary clinics and animal hospitals
Infusion support during veterinary procedures
Perioperative fluid management
Post-operative recovery care
Continuous infusion management for hospitalised animals
The pump supports a flow rate from 0.1 to 1500 ml/h, with adjustment in 0.1 ml/h increments.
This allows the required flow rate to be set according to the intended infusion rather than limiting the pump to a narrow operating range.
The pump supports three infusion modes:
VTBI can be set from 1–9999 ml.
The pump also provides real-time information on infused volume, with bolus and KVO settings available during operation.
The pump is compatible with standard IV sets, allowing it to be incorporated into established infusion workflows.
The available functions include:
Purge function when the pump stops
Bolus function when the pump starts
Adjustable bolus volume from 1 to 20 ml
Keep Vein Open (KVO) function
Infused volume tracking during operation
Flow rate adjustment without interrupting infusion
System memory for repeated operation
The KVO rate can be adjusted from 0.1–5 ml/h.
The pump incorporates several functions for detecting changes in infusion conditions during operation.
An ultrasonic air-in-line detector detects air in the infusion line during operation.
Occlusion sensitivity can be adjusted between high, medium and low levels.
The alarm system includes:
A key lock function is also included to reduce unintended parameter changes.
The pump automatically switches between AC power and its rechargeable battery.
The rechargeable battery provides approximately 5 hours of operation at 30 ml/h.
This allows the pump to continue operating when AC power is temporarily unavailable and provides flexibility when the equipment needs to be moved within the clinical environment.
Wireless management is available as an option.
This provides an additional configuration option for clinical environments where wireless management is required.
Infusion is one part of the wider operating-room setup. During veterinary anaesthesia and surgery, fluid administration may be managed alongside anaesthesia and patient monitoring.
An infusion pump controls fluid delivery. An anaesthesia machine provides anaesthesia and, where applicable, mechanical ventilation.
For operating rooms where these functions need to be arranged together, the Veterinary Anesthesia Machine with Integrated Ventilation includes mounting options for patient monitors, infusion pumps and oxygen concentrators.
This makes the two products relevant to the same operating-room workflow while serving different functions.
Fluid administration and patient monitoring address different parts of perioperative care.
During veterinary anaesthesia and surgery, monitoring may include ECG, HR, RESP, SpO₂, PR, NIBP and TEMP as standard parameters, with additional monitoring options available depending on the configuration.
Our Veterinary Patient Monitor for Anaesthesia and Surgery is a modular veterinary patient monitor designed for anaesthesia, surgery and recovery.
The monitor and infusion pump can therefore be considered separately according to the equipment requirements of the clinical setup.
Infusion management may also form part of post-operative or inpatient care.
For veterinary facilities that need equipment for patient accommodation and recovery, the Veterinary Stainless Steel Kennel Unit with Removable Divider is designed for inpatient care, recovery and temporary patient accommodation.
The kennel system includes an IV pole and can be configured as four individual kennel compartments or one larger lower compartment with the divider removed.
| Pumping Mechanism | Curvilinear peristaltic |
| IV Set Compatibility | Compatible with standard IV sets |
| Flow Rate | 0.1-1500 ml/h (0.1 ml/h increments) |
| Purge & Bolus Rate | 100-1500 ml/h (1 ml/h increments) |
| Accuracy | ±3% |
| Infusion Modes | ml/h, drop/min and time-based modes |
| VTBI | 1-9999 ml |
| Bolus Volume | 1-20 ml |
| KVO Rate | 0.1-5 ml/h |
| Air Detection | Ultrasonic air-in-line detector |
| Alarm Functions | Occlusion, air-in-line, door open, end program, low battery, end battery, AC power off, motor malfunction and system malfunction alarms |
| Wireless Management | Optional |
| Battery | Rechargeable battery, approximately 5 hours operation at 30 ml/h |
| Power Supply | 110/230 V AC, 50-60 Hz |
| Operating Environment | Temperature: 10-40°C; Relative humidity: 30-75%; Atmospheric pressure: 700-1060 hPa |
| Safety Classification | Class I, Type CF |
| Dimensions | 174 × 126 × 215 mm |
| Weight | 2.5 kg |
The flow rate is 0.1 to 1500 ml/h, adjustable in 0.1 ml/h increments.
The pump supports three infusion modes: ml/h, drop/min and time-based. VTBI can be set from 1 to 9999 ml.
Yes. The pump uses a curvilinear peristaltic pumping mechanism and is compatible with standard IV sets.
Yes. An ultrasonic air-in-line detector detects air in the infusion line during operation. The pump also provides adjustable occlusion sensitivity with high, medium and low settings.
The rechargeable battery provides approximately 5 hours of operation at 30 ml/h. The pump automatically switches between AC power and battery operation.
Yes. Wireless management is available as an optional configuration.
The specified accuracy is ±3%.
The pump is classified as Class I, Type CF.
An infusion pump’s value to a distributor is not only in its specifications. The more important question is whether its flow range, infusion modes and alarm functions fit the requirements of the practices and hospitals you serve.
This model is suited to a range of veterinary applications, including fluid therapy, perioperative fluid management, post-operative care and continuous infusion for hospitalised animals.
If you’re evaluating this pump for your veterinary equipment range, we can provide the available product information, technical documentation and configuration details for a specific customer requirement.
For veterinary distributors and professional users, AquaPlat provides:
✓ Product options aligned with specific market and customer requirements
✓ Technical documentation and product information
✓ Support in comparing configurations and product options
✓ OEM branding support where applicable
✓ Reliable manufacturing and supply coordination
Whether you are expanding your veterinary equipment portfolio or looking for an additional supplier option, we can help you evaluate suitable products for your market and requirements.






Get a tailored response within 1 working day.
Please check your inbox for an email from marina@aquaplat.com.
Prefer WhatsApp? +86 191 2421 9461