Veterinary Anesthesia Machine with Integrated Ventilation

Turbine-driven veterinary anesthesia machine with multiple ventilation modes, 10.1-inch touchscreen control and an integrated workstation for surgical anesthesia and mechanical ventilation.

Key Highlights

01
Turbine-Driven Ventilation

02
VCV / PCV / SIMV / VS

03
10.1″ Touchscreen

04
≥120 min Battery

Why This Model?

A More Flexible Approach to Veterinary Anesthesia

For procedures requiring mechanical ventilation, having ventilation, anesthesia and related equipment arranged around one workstation can make the setup easier to manage.

This model combines turbine-driven ventilation, multiple ventilation modes, touchscreen operation and an integrated workstation in a single anesthesia machine.

Key Features

Turbine-Driven Ventilation

The turbine-driven ventilation system operates without an additional driving gas requirement.

Multiple Ventilation Modes

VCV, PCV, SIMV and Volume Support provide different ventilation options, with Manual and ACGO modes also available.

Touchscreen Operation

The 10.1-inch color touchscreen provides an intuitive interface for operating and adjusting the system.

Integrated Workstation

The workstation provides mounting options for patient monitors, infusion pumps and oxygen concentrators, together with a built-in storage basket.

Built Around the Veterinary Anesthesia Workflow

Mechanical Ventilation

The available ventilation modes provide flexibility for procedures requiring mechanical ventilation, including VCV, PCV, SIMV and Volume Support.

Surgical Anesthesia

The integrated breathing circuit with CO₂ absorption, anesthesia vaporizer and ventilation system brings key anesthesia functions together within the workstation.

Operating Room Setup

Mounting options for patient monitors, infusion pumps and oxygen concentrators allow the workstation to be configured around the equipment required for a particular operating room setup.

Key Features

  • 10.1-inch color touchscreen with 1024 × 600 resolution
  • Turbine-driven ventilation system without additional driving gas requirement
  • VCV, PCV, SIMV and Volume Support ventilation modes
  • Manual and ACGO modes
  • Integrated breathing circuit with CO₂ absorption system
  • High-precision anesthesia vaporizer
  • Lithium battery with ≥120 minutes runtime
  • Mounting options for patient monitors, infusion pumps and oxygen concentrators
  • Built-in storage basket
  • Mechanical flowmeter
  • ACGO switch

Ventilation Modes

The machine provides six ventilation and operating modes:

VCV — Volume Control Ventilation

Volume-controlled mechanical ventilation.

PCV — Pressure Control Ventilation

Pressure-controlled mechanical ventilation.

SIMV — Synchronized Intermittent Mandatory Ventilation

Synchronized intermittent mandatory ventilation.

VS — Volume Support

Volume support ventilation.

Manual Mode

Manual ventilation operation.

ACGO Mode

ACGO operating mode.

Technical Specifications

Display
10.1-inch color touchscreen, 1024 × 600 resolution
Ventilation Technology
Turbine-driven ventilation system
Tidal Volume
5 mL – 1500 mL
Ventilation Rate
2 bpm – 60 bpm
Pressure Control Range
5 cmH₂O – 50 cmH₂O
PEEP
OFF, 3 cmH₂O – 30 cmH₂O
Battery
Lithium battery, ≥120 minutes runtime
Oxygen Flush Flow
25 L/min – 75 L/min
Flowmeter Range
0 L/min – 5 L/min
APL Valve Range
1 cmH₂O – 70 cmH₂O
Bellow Capacity
300 mL (small), 1500 mL (large)
Dimensions
1397 × 660 × 622 mm (single vaporizer configuration, excluding breathing system)
Weight
37.5 kg net weight

Complete Your Anaesthesia Setup

Depending on the operating room configuration, oxygen supply and patient monitoring may also need to be considered alongside the anesthesia machine.

Veterinary Oxygen Concentrator

An oxygen concentrator can be considered where an on-site oxygen source is required for veterinary anaesthesia and oxygen therapy.


View Veterinary Oxygen Concentrator for Anaesthesia and Oxygen Therapy →

Veterinary Patient Monitor

A patient monitor can be considered alongside the anesthesia machine for monitoring during anaesthesia and surgical procedures.


View Veterinary Patient Monitor for Anaesthesia and Surgery →

A Good Fit For

  • Veterinary clinics and hospitals performing surgical procedures
  • Operating rooms requiring mechanical ventilation during anesthesia
  • Practices looking for an integrated anesthesia workstation
  • Veterinary equipment distributors evaluating anesthesia equipment for their market

Frequently Asked Questions

Does the ventilation system require additional driving gas?

No. The ventilation system is turbine-driven and does not require an additional driving gas supply.

What ventilation modes are available?

The machine supports VCV, PCV, SIMV and Volume Support, together with Manual and ACGO modes.

What is the tidal volume range?

The tidal volume range is 5 mL – 1500 mL.

What is the battery runtime?

The lithium battery provides a stated runtime of ≥120 minutes.

Can other equipment be mounted on the workstation?

The workstation provides mounting options for patient monitors, infusion pumps and oxygen concentrators.

What is the pressure control range?

The pressure control range is 5 cmH₂O – 50 cmH₂O.

What PEEP range is available?

PEEP can be set to OFF or 3 cmH₂O – 30 cmH₂O.

What is the oxygen flush flow range?

The oxygen flush flow is 25 L/min – 75 L/min.

Why Choose AquaPlat

For veterinary distributors and professional users, AquaPlat provides:

✓ Product options aligned with specific market and customer requirements
✓ Technical documentation and product information
✓ Support in comparing configurations and product options
✓ OEM branding support where applicable
✓ Reliable manufacturing and supply coordination

Whether you are expanding your veterinary equipment portfolio or looking for an additional supplier option, we can help you evaluate suitable products for your market and requirements.

Request A Quick Quote

Get a tailored response within 1 working day.
Please check your inbox for an email from marina@aquaplat.com.

Prefer WhatsApp? +86 191 2421 9461